产品资料

德国科尼克VariTrans P41000隔离器(KNICK)

如果您对该产品感兴趣的话,可以
产品名称: 德国科尼克VariTrans P41000隔离器(KNICK)
产品型号: VariTrans P41000
产品展商: 其它品牌
产品文档: 无相关文档

简单介绍

德国科尼克VariTrans P41000隔离器(KNICK) 铁路应用隔离器 输入:±60 mV, ±90 mV, ±150 mV, ±300 mV, ±500 mV, ±10 V, factory setting: ±10 V,输出:20mA, 10V unipolar/bipolar and 4-20 mA,电源:20 ... 253 V AC/DC


德国科尼克VariTrans P41000隔离器(KNICK)  的详细介绍
德国科尼克VariTrans P41000隔离器(KNICK)
铁路应用隔离器
输入:±60 mV, ±90 mV, ±150 mV, ±300 mV, ±500 mV, ±10 V, factory setting: ±10 V,输出:20mA, 10V unipolar/bipolar and 4-20 mA,电源:20 ... 253 V AC/DC

Specifications

Input data

Inputs

P41000 D1

±60 mV, ±90 mV, ±150 mV, ±300 mV, ±500 mV, ±10 V, factory setting: ±10 V

Calibrated range selection,

P41000 D1-nnn

60mV-100V, unipolar/bipolar

1to16 ranges to customer requirements, calibrated range selection

P41100 D1-nnn

60mV-100V, unipolar/bipolar

Fixed setting to customer requirements

Input resistance

Range ≤0.5 V

Approx. 100 kohms

Range >0.5 V ... 3600V

>2 Mohms

Input capacitance

Range ≤0.5 V

Approx. 10 nF

Range >0.5 V

Approx. 1 nF

Overload

Range ≤10 V

Limited to 36 V by suppressor diode, permissible continuous current = 20 mA

Range >10 V

Limited to 150 V by suppressor diode, permissible continuous current = 3 mA

 

Output data

Output

P 41000 D1

20mA, 10V unipolar/bipolar and 4-20 mA

Calibrated range selection, factory setting: ±10 V

P41000 D1-nnn

20mA, 10V unipolar/bipolar and/or 4-20 mA

Calibrated range selection, to customer requirements

P41100 D1-nnn

20 mA, 10 V unipolar/bipolar or 4-20 mA

Fixed setting to customer requirements

Offset

Factory setting up to ±150 %

Load

With output current

≤12 V (600 ohms at 20 mA)

With output voltage

≤10 mA (1000 ohms at 10 V)

Offset error

<20 µA or 10 mV

Residual ripple

<10 mVrms

     

 Transmission behavior

Gain error

<0.1 % meas. val.

Cut-off frequency (–3dB)

>5 kHz; optional factory setting: 10 Hz

Common mode rejection ratio

Input range ≤1 V

CMRR1)

Approx. 150 dB (DC/AC: 50 Hz)

T-CMRR2)

Approx. 115 dB (1000 V, tr = 1 µs)

Input range >1 V

CMRR1)

DC: approx. 150 dB

AC 50 Hz: approx. 120 dB

Temperature influence 3)

<0.005 %/K full scale

 

Power supply

Power supply

20 ... 253 V AC/DC

AC 48 ... 62 Hz, approx. 2 VA; max. approx. 1.2 W

 

 Isolation

Galvanic isolation

3-port isolation between input, output, power supply

Test voltage

Calibrated range selection

10 kV AC across input and output/power supply

Fixed settings (Model P411xxD1)

15 kV AC across input and output/power supply

All models

4 kV AC output to power supply

Working voltage (basic insulation) to EN 61010-1

Calibrated range selection

Up to 2200 V AC/DC across input, output, and power supply with overvoltage category III and pollution degree 2 (fast transients max. 13.5 kV)

Fixed settings (Model P411xxD1)

Up to 3600 V AC/DC across input, output, and power supply with overvoltage category III and pollution degree 2 (fast transients max. 20 kV)

Rated insulation voltage to EN 50124-1

Calibrated range selection

Up to 2200 V AC/DC across input, output, and power supply with overvoltage category III and pollution degree 2

Fixed settings (Model P411xxD1)

Up to 3000 V AC/DC across input, output, and power supply with overvoltage category III and pollution degree 2

Protection against electric shock

Calibrated range selection

Safe isolation according to EN 61140 by reinforced insulation in accordance with EN 61010-1

Working voltages with overvoltage category III and pollution degree 2:

–up to 1100 V AC/DC across output and power supply

–up to 300 V AC/DC across output and power supply

Fixed settings (Model P411xxD1)

Safe isolation according to EN 61140 by reinforced insulation in accordance with EN 61010-1

Working voltages with overvoltage category III and pollution degree 2:

–up to 1100 V AC/DC across input and output/power supply

–up to 300 V AC/DC across output and power supply

For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.

 

 

 

Standards and approvals

EMC4)

Product standard EN 61326 Emitted interference: Class B Immunity to interference: Industry

Surge withstand

5 kV, 1.2/50 µs, to IEC 255-4 (higher values upon request)

 

Further data

MTBF5)

Approx. 96 years

Ambient

Operation: –10 ... +70 °C

temperature6)

Transport and storage: –40 ... +85 °C

Design

Modular housing

Width 22.5 mm

with screw connectors

See dimension drawing for other measurements

Protection class

Housing IP 40, terminals IP 20

Mounting

Snap-on mounting on 35 mm top-hat rail according to EN 60715

Weight

Approx. 180 g

1) Common-Mode Rejection Ratio =

2) Transient Common-Mode Rejection =

3) Reference temperature for TC specifications = 23 °C, the average TC is always specified

4) Slight deviations are possible while there is interference

5) Mean Time Between Failures - MTBF - to EN 61709 (SN 29500). Conditions: stationary operation in well-tended rooms, average   ambient temperature 40 °C, no ventilation, continuous operation  

6) Extended working temperature range –25 ... +85 °C on request

产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!