输入:±60 mV, ±90 mV, ±150 mV, ±300 mV, ±500 mV, ±10 V, factory setting: ±10 V,输出:20mA, 10V unipolar/bipolar and 4-20 mA,电源:20 ... 253 V AC/DC
德国科尼克VariTrans P41000隔离器(KNICK) 的详细介绍
德国科尼克VariTrans P41000隔离器(KNICK) 铁路应用隔离器 输入:±60 mV, ±90 mV, ±150 mV, ±300 mV, ±500 mV, ±10 V, factory setting: ±10 V,输出:20mA, 10V unipolar/bipolar and 4-20 mA,电源:20 ... 253 V AC/DC
Specifications Input data Inputs | P41000 D1 | ±60 mV, ±90 mV, ±150 mV, ±300 mV, ±500 mV, ±10 V, factory setting: ±10 V | Calibrated range selection, | P41000 D1-nnn | 60mV-100V, unipolar/bipolar | 1to16 ranges to customer requirements, calibrated range selection | P41100 D1-nnn | 60mV-100V, unipolar/bipolar | Fixed setting to customer requirements | Input resistance | Range ≤0.5 V | Approx. 100 kohms | Range >0.5 V ... 3600V | >2 Mohms | Input capacitance | Range ≤0.5 V | Approx. 10 nF | Range >0.5 V | Approx. 1 nF | Overload | Range ≤10 V | Limited to 36 V by suppressor diode, permissible continuous current = 20 mA | Range >10 V | Limited to 150 V by suppressor diode, permissible continuous current = 3 mA |
Output data Output | P 41000 D1 | 20mA, 10V unipolar/bipolar and 4-20 mA | Calibrated range selection, factory setting: ±10 V | P41000 D1-nnn | 20mA, 10V unipolar/bipolar and/or 4-20 mA | Calibrated range selection, to customer requirements | P41100 D1-nnn | 20 mA, 10 V unipolar/bipolar or 4-20 mA | Fixed setting to customer requirements | Offset | Factory setting up to ±150 % | Load | With output current | ≤12 V (600 ohms at 20 mA) | With output voltage | ≤10 mA (1000 ohms at 10 V) | Offset error | <20 µA or 10 mV | Residual ripple | <10 mVrms | | | | | | |
Transmission behavior Gain error | <0.1 % meas. val. | Cut-off frequency (–3dB) | >5 kHz; optional factory setting: 10 Hz | Common mode rejection ratio | Input range ≤1 V | CMRR1) | Approx. 150 dB (DC/AC: 50 Hz) | T-CMRR2) | Approx. 115 dB (1000 V, tr = 1 µs) | Input range >1 V | CMRR1) | DC: approx. 150 dB AC 50 Hz: approx. 120 dB | Temperature influence 3) | <0.005 %/K full scale |
Power supply Power supply | 20 ... 253 V AC/DC | AC 48 ... 62 Hz, approx. 2 VA; max. approx. 1.2 W |
Isolation Galvanic isolation | 3-port isolation between input, output, power supply | Test voltage | Calibrated range selection | 10 kV AC across input and output/power supply | Fixed settings (Model P411xxD1) | 15 kV AC across input and output/power supply | All models | 4 kV AC output to power supply | Working voltage (basic insulation) to EN 61010-1 | Calibrated range selection | Up to 2200 V AC/DC across input, output, and power supply with overvoltage category III and pollution degree 2 (fast transients max. 13.5 kV) | Fixed settings (Model P411xxD1) | Up to 3600 V AC/DC across input, output, and power supply with overvoltage category III and pollution degree 2 (fast transients max. 20 kV) | Rated insulation voltage to EN 50124-1 | Calibrated range selection | Up to 2200 V AC/DC across input, output, and power supply with overvoltage category III and pollution degree 2 | Fixed settings (Model P411xxD1) | Up to 3000 V AC/DC across input, output, and power supply with overvoltage category III and pollution degree 2 | Protection against electric shock | Calibrated range selection | Safe isolation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 Working voltages with overvoltage category III and pollution degree 2: –up to 1100 V AC/DC across output and power supply –up to 300 V AC/DC across output and power supply | Fixed settings (Model P411xxD1) | Safe isolation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 Working voltages with overvoltage category III and pollution degree 2: –up to 1100 V AC/DC across input and output/power supply –up to 300 V AC/DC across output and power supply | For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. |
Standards and approvals EMC4) | Product standard EN 61326, Emitted interference: Class B, Immunity to interference: Industry | Surge withstand | 5 kV, 1.2/50 µs, to IEC 255-4 (higher values upon request) |
Further data MTBF5) | Approx. 96 years | Ambient | Operation: –10 ... +70 °C | temperature6) | Transport and storage: –40 ... +85 °C | Design | Modular housing | Width 22.5 mm | with screw connectors | See dimension drawing for other measurements | Protection class | Housing IP 40, terminals IP 20 | Mounting | Snap-on mounting on 35 mm top-hat rail according to EN 60715 | Weight | Approx. 180 g |
1) Common-Mode Rejection Ratio = 2) Transient Common-Mode Rejection = 3) Reference temperature for TC specifications = 23 °C, the average TC is always specified 4) Slight deviations are possible while there is interference 5) Mean Time Between Failures - MTBF - to EN 61709 (SN 29500). Conditions: stationary operation in well-tended rooms, average ambient temperature 40 °C, no ventilation, continuous operation 6) Extended working temperature range –25 ... +85 °C on request