产品[

PolyTrans P 32000 德国(KNICK)科尼克 变送模块

]资料
如果您对该产品感兴趣的话,可以 sendmsg
产品名称: PolyTrans P 32000 德国(KNICK)科尼克 变送模块
产品型号: PolyTrans P 32000
产品展商: 珠海仪器仪表网
简单介绍
PolyTrans P 32000 德国(KNICK)科尼克 变送模块输入:热电阻,热电偶信号.输出:0 ... 20 mA,4 ... 20 mA,0 ... 5 V,0 ... 10 V.测试电压:2.5KV.电源:24VDC.通讯软件可到KNICK网站下载.


PolyTrans P 32000 德国(KNICK)科尼克 变送模块的详细介绍

PolyTrans P 32000 德国(KNICK)科尼克 变送模块

输入:热电阻,热电偶信号.输出:0 ... 20 mA,4 ... 20 mA,0 ... 5 V,0 ... 10 V.测试电压:2.5KV.电源:24VDC.
Input data Type of sensor Standard Measuring range




Input 1) Pt100 DIN 60751 -200 ... +850 °C
Pt1000 DIN 60751 -200 ... +850 °C
Other platinum resistors DIN 60751 -200 ... +850 °C
Ni100 DIN 43760 -60 ... +180 °C
Other nickel resistors DIN 43760 -60 ... +180 °C


Connection 2-, 3- or 4-wire (automatically recognized)
signaled by a yellow LED


Range of resistance incl. cable resistance for temperature detection: 5 kohms
for resistance detection: 0 ... 5 kohms or 5 ... 100 kohms


Max. cable resistance 100 ohms


Supply current 200 µA, 400 µA or 0 ... 500 µA


Wire monitoring Open circuit detection


Input error limits Resistance <5 kohms: ± (50 mohms + 0.05 % meas. val.) for ranges > 15 ohms
Resistance >5 kohms: ± (1 ohm + 0.05 % meas. val.) for ranges > 50 ohms


Input temperature coefficient <50 ppm/K of selected end value
(medium temperature coefficient in the allowed temperature range, reference temperature 23 °C)


Thermocouples
Input data Type of sensor Standard Measuring range



Input 2) Typ B DIN 60584-1 +250 … +1820 °C
Type E DIN 60584-1 –200 … +1000 °C
Type J DIN 60584-1 –210 … +1200 °C
Type K DIN 60584-1 –200 … +1372 °C
Type L DIN 43710 –200 … +900 °C
Type N DIN 60584-1 –200 … +1300 °C
Type R DIN 60584-1 –50 … +1767 °C
Type S DIN 60584-1 –50 … +1767 °C
Type T DIN 60584-1 –200 … +400 °C
Type U DIN 43710 –200 … +600 °C
W3Re/W25Re ASTM E988-96 0 … +2315 °C
W5Re/W26Re ASTM E988-96 0 … +2315 °C


Input resistance >10 Mohms


Max. cable resistance 1 kohms


Wire monitoring Open circuit detection


Input error limits ± (10 µV + 0.05 % meas. val.) for spans >2 mV


Input temperature coefficient <50 ppm/K of selected end value
(medium temperature coefficient in the allowed temperature range, reference temperatur 23 °C)


Cold junction compensation Internal (Pt100)
Selectable via IrDA®: external (Pt100), fixed value or uncompensated


Error of internal cold junction compensation <1.5 K


Error of external cold junction compensation < 80 mohms + 0.1 % meas. val. by Pt100 for Tcomp= 0 ... 80 °C
Shunt voltages
Input data


Input -1000 ... 1000 mV unipolar/bipolar


Input resistance >10 Mohms


Input error limits ± (200 µV + 0.05 % meas. val.) for spans >50 mV


Wire monitoring Open circuit detection


Input temperature coefficient <50 ppm/K of selected end value
(medium temperature coefficient in the allowed temperature range, reference temperature 23 °C)


Overload 5 V across all inputs
Input data Strain gages


Input ± 7.5 mV/V


Bridge resistance 200 ohms ...10 kohms


Zero adjustment Within input range


Supply current (internal supply) 0 ... 5 mA


Supply voltage (external supply) 1 ... 3 V


Input error limits ± (2 µV/V + 0.1 % meas. val.) for spans ≥0.5 mV/V


Wire monitoring Open circuit and short circuit detection


Input temperature coefficient <50 ppm/K of selected sensitivity
(medium temperature coefficient in the allowed temperature range, reference temperature 23 °C)


Overload 5 V across all inputs
Potentiometers
Input data


Input 200 ohms ... 50 kohms


Connection 3- or 4-wire


Feeding current 0 ... 5 mA


Wire monitoring Open circuit and short circuit detection


Input error limits ± (0.2 % full scale + 0.05% meas. val.) for spans >5 %


Input temperature coefficient <50 ppm/K of selected end value
(medium temperature coefficient in the allowed temperature range, reference temperature 23 °C)
Output data


Outputs 0 ... 20 mA, calibrated switching
4 ... 20 mA, (default 4 ... 20 mA)
0 ... 5 V,
0 ... 10 V


Control range 0 ... approx. 102,5 % span at 0 ... 20 mA, 0 ... 10V and 0 ... 5 V outputs
-1.25 ... approx. 102.5 % span at 4 ... 20 mA output


Resolution 16 bit



Simulation mode 0 ... 20 mA current output: 0 ... 21 mA
adjustable via IrDA® 4 ... 20 mA current output: 3 ... 21 mA
0 ... 5 V voltage output: 0 ... 5.25 V
0 ... 10 V voltage output: 0 ... 10.5 V



Load Current output: ≤10 V (≤500 ohms at 20 mA)
Voltage output: ≤1 mA (≥10 kohms at 10 V)



Output error limits Current output: ± (10 µA + 0.05 % meas. val.)
Voltage output: ± (5 mV + 0.05 % meas. val.)



Residual ripple <10 mVrms


Output temperature coefficient <50 ppm/K of selected end value
(medium temperature coefficient in the allowed temperature range, reference temperature 23 °C)


Error signaling 0 ... 20 mA Output: I =0 mA or ≥21 mA
4 ... 20 mA Output: I ≤3.6 mA or ≥21 mA
0 ... 5 V and 0 ... 10 V Output: V= 0 V or V≥5.25 V and V≥10.5 V respectively
by output signal, red LED and IrDA® for
out-of-range conditions,
incorrect parameter setting,
sensor short-circuit and open circuit
output error load
unintentional adjustment of switches in service (SIL devices)
other device errors. See also "Error signaling".
Transmission behavior


Characteristic Linear rising / falling;
characteristics definable by interpolation points via IrDA® interface


Measuring rate Approx. 3 / s *)
Display


Green LED Auxiliary power


Yellow LED Type of connection
IrDA® communication


Red LED Maintenance request or device breakdown
Power supply 24V DC power supply Broad-range power supply



Power supply 24 V DC (-20 %, +25 %), approx. 1,2 W 24 V ... 110 V DC (±20 %), approx. 1.2 W
Power supply can be routed from one device to another 110 V ... 230 V AC (±10 %), 48 ... 62 Hz, approx. 1.5 VA
via DIN rail bus-connectors.
Isolation


Galvanic isolation 3-port isolation between input, output and power supply


Test voltage 2.5 kV AC, 50 Hz: input against output against power supply


Working voltage Up to 300 V AC/DC across all circuits at overvoltage category II and pollution degree 2 to EN 61010-1
(basic insulation) For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.


Protection against electric Safe Isolation to EN 61140 by reinforced insulation to EN 61010-1.
shock Working voltage across all circuits up to 300 V AC/DC at overvoltage category II and pollution degree 2.
For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
Standards and approvals


Functional safety SIL 2 to IEC 61508, up to SIL 3 when assembled redundantly


Explosion protection ATEX Zone 2 (EN 60079-15)
Class 1, Div 2 / Zone 2 (UL 1604)