产品[
ThermoTrans 205/206 德国(KNICK)科尼克 温度变送器
]资料
如果您对该产品感兴趣的话,可以
产品名称:
ThermoTrans 205/206 德国(KNICK)科尼克 温度变送器
产品型号:
ThermoTrans 205/206
产品展商:
珠海仪器仪表网
简单介绍
ThermoTrans 205/206 德国(KNICK)科尼克 温度变送器隔离变送热电阻信号、输出0...20mA,4...20mA,0...10V,工作电压1000V,测试电压4kV。
ThermoTrans 205/206 德国(KNICK)科尼克 温度变送器的详细介绍
ThermoTrans 205/206 德国(KNICK)科尼克 温度变送器
隔离变送热电阻信号、输出0...20mA,4...20mA,0...10V,工作电压1000V,测试电压4kV。
| Input data
| Sensor type
| Measurement range
| Span (user-defined)
|
|
|
|
|
|
|
| Pt 100 to IEC 751
| –200 ... +850 °C
| 25 ... 1050 K
|
|
| Pt 500
|
|
| Pt 1000
|
|
|
|
|
|
|
| Ni 100 to DIN 43760
| –60 ... +180 °C
| 25 ... 240 K
|
|
| Ni 120
|
|
| Ni 500
|
|
| Ni 1000
|
|
|
|
|
|
|
| Remote resistance sensors
| 0 ... 500 ohms or
| 9 ... 500 ohms or
|
|
| and potentiometers
| 0 ... 5000 ohms
| 90 ... 5000 ohms
|
|
|
|
| Connection
| 2-wire connection: configured
line resistance is calculated in the measured value
|
|
| 3-wire connection:
RL1 = RL4
|
|
| 4-wire connection
|
|
|
|
| Max. line resistance
| RL1 +
RL4 = 100 ohms
|
|
|
|
| Sensor current
| Approx. 1 mA or 0.1 mA
depending on the measuring range
|
|
|
|
| Open-circuit voltage
| <5 V
|
|
|
|
| Sensor failure monitoring
| All inputs for open circuit
|
|
|
|
| Input error limits
| Resistance:
| Range 0 to 500 ohms
| ±0.05 ohm
|
|
|
| Range 0 to 5 kohms
| ±0.5 ohm
|
|
| with Pt:
| Range –200 ... +850 ºC
| ±0.2 K
|
|
| with Ni:
| Range –60 ... +180 ºC
| ±0.2 K
|
|
|
|
| Temperature coefficient
| 0.0025 %/K full scale
(average TC in permitted operating temperature range,
|
| at input
| reference temperature 23
ºC) |
| Output data
|
|
|
|
| Output signal
| Model 205: 0 / 4 ... 20 mA,
impressed current, load voltage ≤10 V
|
| (0 … 100 %)
| Model 206: 0 ... 10 V,
impressed voltage, load current ≤10 mA
|
|
|
|
| Resolution
| Approx. 8000 steps (for 0 ...
100 %)
|
|
|
|
| Control range
| –2.5 % ... 102.5 % of span
|
|
|
|
| Overrange
| Model 205: –1.0 mA or 22 mA
|
| with error message
| Model 206: –0.5 V or 11 V
|
|
|
|
| Output error limits
| 0.1 % full scale
|
|
|
|
| Temperature coefficient
| 0.01 %/K full scale (average
TC in permitted operating temperature range,
|
| at output
| reference temperature 23 ºC)
|
|
|
|
| Residual ripple at output
| <10 mVpp +
digitalization error of input |
| Transmission behavior
|
|
|
|
| Characteristic
| Resistance or
temperature-linear
|
|
| rising or falling
|
|
|
|
| Meas. rate
| Approx. 1 / s
|
|
|
|
| Response time T99
| ≤900 ms
|
|
|
|
| Digital output filter
| T99 = 0 ... 100 s
(1st order filter) |
| Power supply
|
|
|
|
|
| Power supply
| 230 V AC –15 % +10 %, 48 … 62
Hz, approx. 2 VA
|
|
|
|
| Option 336:
| 24 V AC/DC
| AC: –15 % +10 %, 48 … 500 Hz,
approx. 1.5 VA
|
|
|
| DC: –15 % +20 %, approx. 1.2
W
|
|
|
|
| Option 363:
| 115 V AC –15 % +10 %, 48 … 62
Hz, approx. 2 VA |
| Isolation
|
|
|
|
|
| Galvanic isolation
| 3-port isolation between
input, output and power supply
|
|
|
|
| Test voltage
| 4 kV AC (input against output
and power supply)
|
|
| 3 kV AC (output against power
supply)
|
|
|
|
| Working voltage
| 1000 V AC/DC input against
output and power supply with overvoltage category II
|
| (basic isolation)
| and pollution degree 2,
|
|
| 330 V AC/DC output against
power supply with overvoltage category II and
|
|
| pollution degree 2 according
to EN 61010-1
|
|
| For applications with high
working voltages, you should ensure there is sufficient
|
|
| spacing or isolation from
neighboring devices and protection against electric shocks.
|
|
|
|
| Protection against electri
| Safe isolation according to
EN 61140 by reinforced insulation in accordance with
|
| shock
| EN 61010-1.
|
|
| Working voltages with
overvoltage category II and pollution degree 2:
|
|
| 600 V AC/DC for input against
output and power supply
|
|
| with overvoltage category II
and pollution degree 2:
|
|
| 300 V AC/DC for output
against power supply.
|
|
| For applications with high
working voltages, you should ensure there is sufficient
|
|
| spacing or isolation from
neighboring devices and protection against electric shocks. |
| Standards and approvals
|
|
|
|
|
| Surge withstand
| 5 kV 1.2 / 50 µs according to
IEC 255-4
|
|
|
|
| EMC 1)
| EMC directive 89/336/EEC, EN
61326; NAMUR recommendation NE 21 |
| Other data
|
|
|
|
| Interface
| Optical, interface adapter on
RS 232 interface (PC) is included in the
|
| (only user-definable models)
| ZU 0254 communications kit
|
|
|
|
| Ambient temperature
| Operation:
| –10 ... +60 ºC
|
|
| Transport and storage:
| –30 ... +80 ºC
|
|
|
|
| Housing
| Modular housing A7, width
22.5 mm, screw terminals
|
|
| See dimension drawings for
further dimensions
|
|
|
|
| Protection class
| Housing IP 40, terminals IP
20
|
|
|
|
| Mounting
| With snap-on mounting for 35
mm top hat rail according to EN 50022-35,
|
|
| width 22.5 mm, see dimension
drawings for conductor cross section
|
|
|
|
| Weight
| Approx. 300 g
|
|
|
|
|
|
|
| 1) Slight deviations are
possible while there is interference from RF radiation |
ThermoTrans 205/206 德国(KNICK)科尼克 温度变送器